Carbon monoxide at work

Carbon monoxide is a toxic gas that can be generated during combustion and accumulate in workplaces. Because it is colorless and odorless, preventing carbon monoxide exposure requires identifying sources and controlling exposure without relying on the senses.

In short

Engines, generators, and combustion equipment can produce carbon monoxide. Avoiding their improper use indoors and controlling emissions, ventilation, and detection are essential measures.

Content
  1. What it is and why it is dangerous
  2. Job sources that need to be identified
  3. Situations that favor exposure
  4. Prevention at the source
  5. Measurement, detection and alarms
  6. Warning signs and response
  7. Practical example
  8. Common mistakes and follow-up
  9. Underground car parks: sources and the people actually exposed
  10. Vehicle workshops: tailpipe extraction and the limitations of catalysts
  11. Environmental detection and medical assessment provide different information
  12. Suspected poisoning: respond without creating additional casualties
  13. Re-entry, investigation and follow-up after the incident
  14. Related concepts
  15. On the blog
  16. References

A–Z Dictionary

What it is and why it is dangerous

Carbon monoxide, identified as CO, is a toxic gas that can be produced by the incomplete combustion of carbon-containing materials. It should not be confused with carbon dioxide, CO2: they are distinct agents with different hazards and detection systems. An assessment that only considers one does not automatically rule out exposure to the other.

Carbon monoxide (CO) does not offer a reliable warning through smell or color. A person can be exposed without recognizing it and lose the ability to react before leaving the area. Prevention should focus on the sources and conditions of accumulation, avoiding relying on the senses of those working as a warning system.

Job sources that need to be identified

Potential sources include combustion engines, generators, power tools, vehicles, heating equipment, and thermal processes. The assessment should include owned, rented, and contractor-operated equipment. A machine temporarily brought in for maintenance can create a scenario that was not present during normal operation.

The location of gas discharges is also studied. An external source can affect the interior if its emissions reach an air intake, door, or opening. Location, operation, and surrounding environment are all important factors, not just whether the equipment is outdoors. Occupied areas near the main work area must also be considered.

Situations that favor exposure

Indoor spaces, partially enclosed areas, and rooms with insufficient ventilation can promote accumulation. Opening a door or noticing air movement alone does not prove that the concentration is safe. The geometry, the amount emitted, and changes in conditions all influence the outcome.

Confined spaces require a specific assessment and procedure that covers all their hazards. However, the risk of CO exposure is not limited to confined spaces: it can occur in a warehouse, construction site, or ordinary work area. The expected duration of exposure does not justify ignoring it, because a dangerous concentration can develop rapidly.

Prevention at the source

The first step is to avoid introducing a CO source in a location where it could expose people. When feasible, electric, battery-powered, or other technically suitable alternatives are studied, also assessing their risks. NIOSH advises against using gasoline-powered equipment in buildings or partially enclosed areas due to the risk of carbon monoxide accumulation.

Combustion equipment and its exhaust systems must be maintained and operated safely. Ventilation and extraction require proper design and testing, not an assumption based on room size. Temporary work plans must identify who authorizes the equipment, where it is located, and how protection is maintained throughout the task.

Measurement, detection and alarms

The assessment determines when measurements or continuous detection are needed and what equipment is suitable for CO. Range, location, maintenance, functional checks, and alarm response must be considered. A detector for another gas should not be assumed to be capable of measuring CO if that function is not specified and verified.

Action levels are established by competent personnel, taking into account the purpose of the system, the assessment, and applicable standards. Occupational exposure levels should not be used as alarm settings without analysis. The presence of a detector does not authorize unsafe work practices, nor does it replace emissions control.

Warning signs and response

Exposure may be accompanied by headache, dizziness, nausea, confusion, or loss of consciousness, among other effects. These are nonspecific signs and do not, on their own, confirm the cause. If exposure is suspected or an alarm is triggered, the area is evacuated to uncontaminated air, and the established emergency response is activated.

Urgent assistance is requested by calling the local emergency number, 112 in Spain. Do not re-enter the area or attempt an improvised rescue that could endanger others. Intervention in a hazardous atmosphere requires trained personnel and appropriate equipment. Resuming work requires eliminating the cause and verifying the conditions according to the established procedures.

Practical example

In this hypothetical example, a contractor proposes using a combustion-engine-powered cleaning machine inside a work area. Before starting, the coordination team discovers that emissions were not accounted for in the plan. Alternatives are reviewed, and a system is selected that avoids bringing the engine inside, with an evaluated exterior location away from potentially affected air intakes.

The planning process also identifies nearby occupied areas, communication between teams, and suspension criteria. Actual execution is verified, not just prior documentation. If the location or equipment changes, the authorization is reviewed: safety depends on the entire scenario, not on having performed similar work previously without incident.

Common mistakes and follow-up

The most dangerous mistakes are relying on smell, considering an open door sufficient, or thinking that a small motor cannot generate significant exposure. Another dangerous mistake is confusing a household or other contaminant detector with a system validated for the required workplace purpose.

Monitoring reviews source inventory, maintenance, temporary work, and practical alarm training. Every incident or equipment change must be added to the assessment. Information on CO (carbon monoxide) must also reach purchasing, leasing, and contractors to prevent a new source from appearing on the job without its consequences being anticipated.

Underground car parks: sources and the people actually exposed

In an underground car park, assessment should connect emissions with people’s presence during different activities. Vehicle movements, waiting with engines running, maintenance and temporary equipment all matter. Security, cleaning, payment or repair staff may remain much longer than a driver who parks and leaves. Connected rooms, workstations near ramps and regular walking routes also need consideration. An assessment focused only on the number of parking spaces may overlook who breathes the air, for how long and under which operating conditions throughout the working day.

Installed ventilation must be checked against actual use and changes in activity. The existence of a fan, or successful operation at commissioning, is insufficient. Faults, obstructions, poorly served zones and the effects of doors or other modifications need to be understood. Compliance with building requirements does not replace assessment of a particular task. For example, cleaning with gasoline-powered equipment can introduce a substantial source unrelated to normal vehicle traffic. Its introduction therefore requires a specific review rather than an assumption that ordinary ventilation will accommodate it.

Before contractor work begins, preventive information exchange should identify the proposed equipment, fuel, location, exhaust arrangements and nearby people. Spain’s Royal Decree 171/2004 requires information on concurrent risks before work and when relevant circumstances change. Authorization cannot rely solely on the machine having a CE mark. If adequate conditions cannot be ensured, the method should be changed or the task postponed. Electrical or battery alternatives should be assessed with their own hazards in mind, maintaining effective control throughout the intervention and communicating any subsequent changes.

Vehicle workshops: tailpipe extraction and the limitations of catalysts

In a workshop, running an engine for diagnostics or checks requires planning how exhaust gases will be captured. The UK HSE recommends connecting extraction to the tailpipe during stationary running and discharging to a safe outdoor location. Connections, hoses and compatibility with the vehicle need checking. The arrangement must prevent gases returning through air intakes or affecting other people. This is a useful technical reference whose application must be integrated with the actual risk assessment and Spanish requirements, rather than presented as British law applying to a Spanish workshop.

A catalytic converter does not justify assuming that an engine can run uncontrolled indoors. HSE warns that performance can be lower with relatively cool exhaust gases and that a converter does not remove every exhaust contaminant. The absence of visible smoke is also not evidence that CO is absent. Extraction and ventilation should protect people at adjacent workstations, inspection pits and other connected areas. Intermittent or short tests belong in the assessment; they do not automatically qualify for an exemption from the necessary preventive measures.

Review should include occasional operations: starting faulty vehicles, rented combustion equipment, generators used during power failures and changes to workshop layout. A straightforward instruction should state which checks precede work, who reports faults and which conditions prevent continuing. Adaptors or exhaust arrangements that could detach during testing should not be improvised. Training should help people recognize a deficient connection and stop work without waiting for smell, discomfort or symptoms to reveal a problem. A task’s familiarity does not remove the need to check its actual conditions.

Environmental detection and medical assessment provide different information

An environmental detector reports on the contaminant and location for which it is designed; it does not itself diagnose poisoning. Selection should consider function, range, placement, maintenance and the intended response. A domestic sensor or CO₂ instrument does not automatically become suitable equipment for a CO-exposed workplace. The plan should establish who checks operation, how faults are recognized and what an alarm requires, including communication with people working where the warning might not be noticed. A detector is one part of the arrangement, rather than authorization to create an uncontrolled source.

Occupational exposure limits, alarm settings and re-entry criteria answer different questions. They should not be interchanged without competent assessment. A low spot reading, taken far from the source or after ventilation, also does not necessarily reconstruct earlier exposure. Time, location, operating conditions and possible instrument problems should be retained. Records support investigation and verification, but do not justify keeping someone in a suspected hazardous situation while trying to obtain a more conclusive number. An instrument reading must be interpreted together with the circumstances in which it was obtained.

Exposure history and symptoms are central to medical assessment. CDC guidance explains that a conventional two-wavelength pulse oximeter is unreliable when carboxyhemoglobin is present; an apparently normal reading does not exclude poisoning. Specific tests and their interpretation belong with health professionals, who consider time since leaving the environment and care already provided. Severity is also not determined by a carboxyhemoglobin figure alone. These limitations support seeking medical assistance rather than attempting to diagnose or clear a symptomatic colleague using an ordinary workplace first-aid device.

Suspected poisoning: respond without creating additional casualties

An alarm, compatible symptoms or several people feeling unwell near a combustion source should activate the planned response. Leave for uncontaminated air and request urgent assistance, using 112 in Spain. Do not delay departure to finish a test or retrieve monitoring equipment. From a safe location, communicate the address, possible source, number of affected people and whether anyone remains inside. This information helps emergency services prepare their intervention. A worker should not have to establish a definitive diagnosis before reporting a credible concern and leaving the affected area.

Do not enter to rescue someone or return to switch off a machine if doing so would expose you. A remote stop may be used only when it can be operated without approaching the hazardous atmosphere or delaying evacuation. FFP2 and FFP3 masks protect against particles, not CO; an organic-vapor cartridge must not be assumed suitable for that gas either. Intervention in an unknown atmosphere requires organization, trained personnel and specialized protection. Wanting to help does not turn ordinary workshop protective equipment into suitable rescue equipment.

A symptomatic person should not drive themselves to a healthcare facility. Assistance and transport should be coordinated according to emergency-service instructions. If first aid is needed, trained people should provide it under safe conditions without bringing others into the affected area. Article 20 of Spain’s Prevention Law and Article 7 of Royal Decree 374/2001 require preparation of equipment, responsibilities and links with external services. That preparation should be practiced without creating actual exposure or making improvised rescue an accepted part of the workplace response.

Re-entry, investigation and follow-up after the incident

Symptoms disappearing or an alarm becoming silent does not independently authorize a return to work. The source must be controlled, ventilation checked and the atmosphere assessed through the competent procedure. The review should also consider whether conditions will change again when equipment restarts or normal activity resumes. Whoever authorizes resumption needs evidence of control, rather than merely being told that a door was opened. Access restrictions and planned measures remain in place while danger persists, and people should know who can communicate a verified decision to resume.

Investigation reconstructs equipment use, operating conditions, timing, people’s locations, ventilation and alarms. It also examines recent changes, contractor activities and communication failures. The objective is to identify decisions and barriers needing correction, with assigned responsibilities and subsequent verification of effectiveness. Replacing a detector battery is insufficient if the source continues to be used improperly. Relevant preventive information should be shared with affected teams while medical information is kept separately. The person who became ill should not be blamed for failing to detect an odorless gas.

Clinical follow-up is organized according to medical assessment and discharge advice. CDC guidance warns about possible delayed neurological complications; feeling better initially does not replace information on warning signs and appropriate review. Return to work should consider medical conclusions and the conditions actually corrected. The employer can verify preventive measures and collective learning without unrestricted access to medical histories. Closing the administrative incident record does not demonstrate that the exposure scenario can no longer recur, or that every affected person has completed the necessary individual follow-up.

Related concepts

On the blog

References

  1. Official State Gazette. Royal Decree 374/2001, on protection against chemical agents at work. Consolidated text. Official source
  2. National Institute for Occupational Safety and Health. Carbon Monoxide Hazards at Work. Updated October 2026. Official source
  3. National Institute for Occupational Safety and Health. Occupational exposure limits for chemical agents in Spain. 2026 Edition. Official Source
  4. HSE: Vehicle exhaust emissions in motor vehicle repair Official source
  5. CDC: Clinical Guidance for Carbon Monoxide Poisoning, August 2026 review Official source
  6. SafeWork NSW: Carbon monoxide exposure alert, 29 October 2026 Official source
  7. INSST-CNMP: respiratory protection and the specific issue of carbon monoxide (2022 note) Official source
  8. Royal Decree 171/2004: preventive information exchange between concurrent employers Official source
  9. Law 31/1995: emergencies, serious and imminent risk, and health surveillance Official source

Editorial information

Publication date: October 10, 2026.

Last updated: 8 November 2026.

Editorial responsibility: Sabentis editorial team.