Smoke control during a fire

Measures to limit or remove smoke and heat, preserve evacuation conditions and support firefighting.

In brief

Measures to limit or remove smoke and heat, preserve evacuation conditions and support firefighting.

Contents
  1. What smoke control aims to achieve
  2. Different strategies
  3. Interaction with doors and other systems
  4. Maintaining design conditions
  5. Example in an industrial building
  6. Scope of protection
  7. Related concepts
  8. References

A–Z dictionary →

What smoke control aims to achieve

These systems limit the accumulation or spread of fire products to support design objectives such as evacuation and firefighting. Smoke reduces visibility and may incapacitate people before flames reach them. An ordinary air-conditioning system does not become a smoke-control system simply by increasing fan speed.

Related concept: Fire protection systems.

Different strategies

Natural or mechanical extraction, differential pressurisation or horizontal ventilation may be used, depending on the building and purpose. Some solutions aim to maintain a smoke-free layer; others prevent smoke entering a protected route. The strategy determines openings, replacement air, barriers, ducts and equipment. Combining solutions without analysis may move smoke into places that were meant to remain protected.

Interaction with doors and other systems

Air entry and door positions affect performance. Interactions with sprinklers, detection and compartmentation are also studied. Excess pressure may make a door difficult to open, while insufficient pressure may fail to control smoke entry. Activation sequences and the scenarios considered form part of the technical justification.

Maintaining design conditions

Checks cover obstructions, partition changes and objects preventing a barrier from descending. Tests include automatic and manual activation, standby position, signals and component responses. Any unavailability must be recorded and restoration checked. Creating openings or modifying fans during refurbishment can change the behaviour of the complete system.

Example in an industrial building

A hypothetical industrial building gains a mezzanine beneath an extraction area. The new structure interrupts smoke movement and changes the scenarios. The review must analyse the whole system and its coordination with evacuation. Keeping the same number of extractors does not demonstrate that the solution remains effective.

Scope of protection

Smoke control does not mean a space can be traversed during every fire. Effectiveness is assessed against defined scenarios and conditions. In Spain, the RIPCI and the building framework guide requirements, but the design must resolve each application. Occupants follow emergency instructions and must not use the presence of extraction as a reason to remain.

References

  1. BOE: Reglamento de instalaciones de protección contra incendios. Official source
  2. CTE: Documento Básico SI con comentarios. Official source

Editorial information

Publication date: 1 November 2026.

Editorial responsibility: Sabentis Editorial Team.

Author: Pablo RodríguezLinkedIn

Executive Vice President of the ORP International Foundation and Chief Financial Officer of Sabentis.

Request a Demo

Discover all that Sabentis can do for your organization.

Try Sabentis

request a demo
stars 5
GetApp Software Advice Capterra