Workplace lighting

Workplace lighting encompasses all the natural and artificial lighting conditions that allow people to safely perceive their tasks, surroundings, obstacles, signals, and controls without eye strain. It includes the level of illumination (illuminance, measured in lux), its uniformity, the absence of direct and reflected glare, the balance of luminance between the task and its environment, color rendering, light direction, and the absence of flickering and stroboscopic effects. Inadequate lighting increases errors and accidents (falls, bumps, contact with moving parts), causes eye strain, headaches, and awkward postures to see better, and is related to performance and comfort. In Spain, Royal Decree 486/1997 on workplaces establishes in its Annex IV the minimum lighting levels according to the visual requirements of the task and the conditions that the facilities must meet, Royal Decree 488/1997 regulates lighting in work with display screens and the UNE-EN 12464-1 standard establishes the technical design criteria for lighting in indoor workplaces.

In short

A set of lighting conditions, both natural and artificial, that allow for the safe and fatigue-free perception of tasks, surroundings, and signals: illumination level, uniformity, absence of glare, luminance balance, color rendering, and flicker-free illumination. Royal Decree 486/1997 establishes minimum levels (100, 200, 500, and 1,000 lux depending on visual requirements; 25 to 100 lux in passageways and walkways), doubled in areas with a risk of accidents, and conditions for uniformity, glare, and emergency lighting; Royal Decree 488/1997 regulates lighting on display screens, and UNE-EN 12464-1 establishes design criteria.

Content
  1. Minimum levels and conditions of Royal Decree 486/1997
  2. Lighting quality factors
  3. Specific situations
  4. Organizational application: how to manage lighting in the company
  5. Limits and common mistakes
  6. Practical example
  7. Regulatory and reference framework
  8. Related concepts
  9. References

A–Z dictionary →

Minimum levels and conditions of Royal Decree 486/1997

Annex IV of Royal Decree 486/1997 establishes that the lighting of each area or part of a workplace must be adapted to the characteristics of the activity, taking into account the safety and health risks dependent on visibility conditions and the visual demands of the tasks. Whenever possible, workplaces shall have natural lighting, supplemented by artificial lighting when the former does not guarantee adequate visibility conditions, and general artificial lighting shall be used preferentially, supplemented by localized lighting when high levels are required in specific areas.

The minimum illumination levels set are 100 lux in areas where tasks with low visual demands are performed, 200 lux for moderate demands, 500 lux for high demands, and 1,000 lux for very high demands; 50 lux in areas or premises of occasional use and 100 lux in those of regular use; and 25 lux in circulation routes of occasional use and 50 lux in those of regular use, measured at the height of the task or, in circulation routes, at ground level. These levels must be doubled when there are appreciable risks of falls, collisions, or other accidents, or when a visual perception error could pose a danger, or when the contrast between the object and the background is very weak.

The standard also requires that the distribution of lighting levels be as uniform as possible, that adequate luminance levels and contrasts be maintained between the task and its surroundings, that direct glare from sunlight or high-luminance artificial sources and indirect glare from reflective surfaces be avoided, that systems that impair the perception of contrast, depth, or distance not be used, and that areas where a lighting failure poses a risk be equipped with emergency, evacuation, and safety lighting. The INSST technical guide on workplaces and NTP 211 further develop these criteria.

Lighting quality factors

  • Illumination level. Illuminance maintained in the task according to UNE-EN 12464-1 (for example, 500 lux for office work with reading and writing, 750 or more for precision tasks), with the legal minimums of Royal Decree 486/1997 as the floor.
  • Uniformity. Relationship between the minimum and average illuminance in the task area and its immediate surroundings, avoiding dark areas and sharp contrasts.
  • Glare. Direct (light sources or windows in the field of vision) or reflected (glossy surfaces, screens); it is controlled with shielding, orientation of luminaires, blinds, matte finishes and arrangement of workstations.
  • Luminance and contrast. Balance between the luminance of the task, the immediate environment and the background to avoid continuous visual adaptations and fatigue.
  • Color rendering and color temperature. Color rendering index appropriate for the task (essential in quality control, healthcare, graphic arts) and color temperature consistent with the lighting level and the use of the space.
  • Flickering and stroboscopic effect. Electronic sources and equipment that prevent perceptible flickering and the stroboscopic effect on rotating machinery, which can make moving elements appear stationary.
  • Natural lighting. Taking advantage of daylight with glare and overheating control, and complemented with adjustable artificial light.
  • Maintenance. Cleaning of light fixtures and surfaces, replacement of lamps and monitoring of the maintenance factor to maintain design levels.

Specific situations

  • Display screens. Royal Decree 488/1997 requires that general and localized lighting guarantee adequate levels and contrasts between the screen and the environment, and that reflections and glare on the screen are avoided by the arrangement of the workstation with respect to windows and light fixtures.
  • Precision tasks. Complementary localized lighting with glare and shadow control, and high levels according to UNE-EN 12464-1.
  • Industry and workshops. Lighting of machinery and risk areas, prevention of the stroboscopic effect, doubling of levels in areas with risk of accidents and emergency lighting.
  • Warehouses and logistics. Adequate levels in aisles, docks and picking areas, uniformity in high shelving and lighting transition between interior and exterior.
  • Night and outdoor work. Lighting of roads, access points and outdoor work areas according to the activity, with attention to safety and fatigue.
  • People with special needs. Adaptation of levels and contrasts for older workers or those with visual limitations, in accordance with the principle of adapting the work to the person.

Organizational application: how to manage lighting in the company

  1. Classify the positions and areas according to visual requirements and risks associated with visibility, and determine the required lighting levels in accordance with Royal Decree 486/1997 and UNE-EN 12464-1.
  2. Measure the illuminance in the task and in the traffic routes with a calibrated lux meter, under representative conditions and considering natural light, and evaluate uniformity, glare and reflections.
  3. Correct the deficiencies by redesigning the installation (number, type and arrangement of luminaires, localized lighting), controlling glare (shielding, blinds, finishes) and relocating workstations with respect to windows and luminaires.
  4. Verify the workstations with display screens in accordance with Royal Decree 488/1997 and its technical guide.
  5. Ensure emergency and evacuation lighting in places where a failure poses a risk, with periodic checks.
  6. Establish the maintenance program for the lighting installation: cleaning, lamp replacement, and level checks.
  7. Consult with workers, collect complaints of eye strain or glare, and review lighting when layout, tasks, or equipment changes.

Preventive management software allows you to record lighting measurements by workstation and zone, compare them with required levels, plan corrective actions and maintenance of the installation, and document reviews of workstations with screens.

Limits and common mistakes

  1. Meeting the minimum legal level without considering the actual demands of the task or the duplication of levels in areas with a risk of accident.
  2. Placing workstations with screens in front of windows or under unshielded lights, with reflections and glare.
  3. Measure at a single point or without considering the variation of natural light throughout the day.
  4. Neglecting maintenance: dirty light fixtures, burnt-out lamps, and levels far below design specifications.
  5. Ignore the stroboscopic effect in areas with rotating machinery or the flickering of deteriorated equipment.
  6. Forgetting emergency and evacuation lighting or not checking it periodically.

The detailed conditions are set out in Annex IV of Royal Decree 486/1997, in Royal Decree 488/1997 and in the INSST technical guides; this sheet is for informational purposes.

Practical example

Situation: An electronics assembly company receives complaints of eye strain and inspection errors on the quality control line and detects a tripping incident in a poorly lit side aisle.

  • Evaluation. The prevention service measures the illuminance: 350 lux in the visual inspection stations, a task with very high demands that requires at least 1,000 lux, and 20 lux in the side corridor, which is in regular use and has a risk of tripping due to cables and boxes.
  • Analysis. Reflections were also identified on the metal inspection trays from unshielded luminaires, and a perceptible flicker was found in two deteriorated luminaires.
  • Measures. Localized adjustable lighting with diffusers and glare control is installed at the inspection stations, deteriorated luminaires are replaced, the lighting of the corridor is reinforced to exceed the 100 lux required due to the risk of falls, and the storage that encroached on the passageway is reorganized.
  • Follow-up. New measurements confirm the levels, inspection errors and complaints decrease, and lighting is incorporated into the maintenance program and the annual job review.

Regulatory and reference framework

The UNE-EN 12464-1 standard establishes the lighting requirements for indoor workplaces and the UNE-EN 12464-2 those for outdoor workplaces; the UNE-EN 1838 regulates emergency lighting and the Technical Building Code the requirements in buildings.

Related concepts

References

  1. Official State Gazette. Royal Decree 486/1997, of April 14, establishing the minimum health and safety requirements in the workplace. 1997, current consolidated text. Official source
  2. Official State Gazette. Royal Decree 488/1997, of April 14, on minimum health and safety requirements for work with equipment including display screens. 1997, current consolidated text. Official source
  3. National Institute for Occupational Safety and Health. Technical guide for the assessment and prevention of risks related to the use of workplaces. Official source
  4. National Institute for Occupational Safety and Health. Technical guide for the assessment and prevention of risks related to the use of display screen equipment. 2021. Official source
  5. National Institute for Occupational Safety and Health. NTP 211: Lighting of workplaces. 1989. Official source

Editorial information

Publication date: August 30, 2026 .

Editorial Manager: Sabentis Editorial Team .

Editorial review by Pablo Rodríguez LinkedIn

Executive Vice President of the ORP International Foundation and Chief Financial Officer of Sabentis.

Request a Demo

Discover all that Sabentis can do for your organization.

Try Sabentis

request a demo
stars 5
GetApp Software Advice Capterra