Spain · National · Resolution

Resolution of 18 November 2010 · Wheeled loader inspection

In force, as amended in 2015

Official Spanish title: Resolución de 18 de noviembre de 2010, de la Dirección General de Política Energética y Minas, por la que se aprueba la especificación técnica número 2010-1-01 "Inspección de cargadoras sobre ruedas" de la instrucción técnica complementaria 02.2.01 "Puesta en servicio, mantenimiento, reparación e inspección de equipos de trabajo" del Reglamento General de Normas Básicas de Seguridad Minera, aprobada por la Orden ITC/1607/2009, de 9 de junio.

On this page
  1. What it regulates
  2. Who it applies to
  3. Key provisions
  4. History and versions
  5. Transitional provisions and application notes
  6. Official BOE legal relationships
  7. Official sources
  8. Explore the concepts in Sabentis Explore

What it regulates

Adopts the technical procedure for periodic inspection of wheeled loaders in mining. It connects the condition of safety systems to defect assessment and the measures needed before continued machine use.

Who it applies to

Wheeled loaders within technical specification 2010-1-01 and mining instruction 02.2.01; machines expressly designed for tunnels or galleries are excluded.

Key provisions

Technical specification 2010-1-01 sets inspection points and methods for wheeled loaders. It excludes machines expressly designed for use inside tunnels or galleries. Other loader attachments may fall within its definition, but this does not automatically extend the procedure to every mining machine.

Specification: scope

Intervals come from the general instruction: first inspection three years after commissioning; then every three years up to six years of age, every two years above six and up to ten, and annually above ten or where age cannot be demonstrated. First-use dates require documentary evidence; otherwise the manufacturing date is used.

Instruction 02.2.01, section 5.2: intervals

Inspection covers documentation, access, the operator’s station, protective structures, steering, braking and other safety-related systems. The annexes address test stages, defect classification, measures, personnel and safe testing. Annex VII requires control of the test area and machine movements, including equipment locking where applicable.

Inspection and preventive measures

An unfavourable result prevents the machine being made available to workers until defects are remedied. A negative result requires an immediate stop. Both cases require a further favourable inspection, with or without minor deficiencies, before return to service. The employer retains the certificate and register; mining inspection does not replace public-road vehicle inspections.

Instruction 02.2.01, section 5.3: result

The Resolution of 19 December 2014, published on 7 January 2015, amended Annexes I, IV, VIII and X. Inspection preparation must incorporate those changes to measurements, assessment criteria, the inspection form and the rating method, rather than rely only on the original 2010 document.

Amendment applicable since 2015

History and versions

BOE publication: 22/12/2010 · Initial entry into force: 22/06/2011

BOE-A-2010-19694

Specification published in December 2010 with an initial six-month period; amended with effect from 8 January 2015.

Published on 22 December 2010. The second provision sets effectiveness six months after publication, giving 22 June 2011 from the operative text. The discrepancy in the BOE analysis note is recorded separately.

BOE-A-2010-19694

Published on 7 January 2015 and applicable from 8 January 2015. It amends Annexes I, IV, VIII and X of the specification and is the only subsequent amendment recorded in the BOE analysis consulted.

BOE-A-2015-145
Text versions incorporated into the receiving legislation

Dates and links refer to articles of the amended legislation. This table does not represent a separate consolidated text of the amending instrument.

PublicationEffective dateOfficial referenceAffected provisions
17/06/200918/06/2009BOE-A-2009-10086Section 5 · Technical inspection of machinery

Transitional provisions and application notes

  • The BOE analysis note gives 22 June 2010, a date preceding publication. The second provision of the official text specifies six months from 22 December 2010, giving 22 June 2011. This summary follows the operative period and makes the discrepancy explicit; it does not treat the note as a valid commencement date.

    Discrepancy in the effective date
  • No consolidated text of this instrument was available in the service checked. Read the 2010 original together with its 2015 amendment and instruction 02.2.01. This summary does not reproduce the rating tables or replace the complete procedure, risk assessment or manufacturer’s instructions.

    Combined reading and limits of this summary

Official BOE legal relationships

Relationships may affect only specific provisions. They do not by themselves determine the status of the whole instrument: consult its history and application notes.

Earlier references (1)
Subsequent references (1)

Official sources

Official sources checked on 16/11/2026. Updating a database record does not by itself mean that the legislation has been amended.

  1. BOE-A-2010-19694 · Original text
  2. ELI identifier
  3. BOE-A-2009-10086 · Original text
  4. BOE-A-2009-10086 · Consolidated text
  5. BOE-A-2015-145 · Original text

Official sources checked on 16 November 2026. No consolidated text of this instrument itself is offered: links lead to the original publication, amendments and, where relevant, the consolidated instrument receiving the changes. A register update is not an amendment.

Sabentis editorial summary and unofficial translation of Spanish legislation; it does not replace the official text.

Editorial information

Publication date: 16 November 2026.

Editorial responsibility: Sabentis editorial team.

Editorial review by Pablo RodríguezLinkedIn

Executive Vice President of the International ORP Foundation and Chief Financial Officer of Sabentis.

Request a Demo

Discover all that Sabentis can do for your organization.

Try Sabentis

request a demo
stars 5
GetApp Software Advice Capterra