Occupational risks in data centres

A data centre brings together IT equipment, electrical supplies, backup systems and cooling. Although its service is digital, the facility requires physical work and maintenance with their own risks. Assessing them requires understanding each task and the energy sources present, alongside service continuity needs.

In brief

Data centres combine electricity, heavy equipment, cooling, noise and maintenance tasks. Prevention must consider employees and contractors, backup energy, access and emergencies. Keeping the service available never removes the need to plan safe work.

Contents
  1. Which tasks and people must be assessed
  2. Electricity and backup sources
  3. Handling, access and the physical environment
  4. Noise, thermal conditions and organisation
  5. Emergencies and coordination of interventions
  6. Hypothetical example: replacing backup equipment
  7. Related concepts
  8. References

A–Z dictionary →

Which tasks and people must be assessed

Assessment covers server installation, cabling, cleaning, electrical and cooling maintenance, batteries and breakdown response. It includes technical personnel, security staff and contractors, with attention to work outside normal hours.

Reusing an office risk assessment is not enough. Review technical rooms, access, rack operations and the conditions of each intervention. Risks vary with the design and installed technology; not all centres have the same systems or need identical measures.

Electricity and backup sources

Identify the main supply, uninterruptible power supplies, batteries and other sources capable of maintaining energy. A partial shutdown does not demonstrate the absence of voltage. Service continuity must be planned alongside isolation and people’s safety.

In Spain, Royal Decree 614/2001 establishes de-energised working as the general rule for activities involving electrical risk, subject to regulated exceptions and conditions. Interventions require appropriate personnel and procedures. Live operations must not be improvised to avoid a service interruption.

Handling, access and the physical environment

Servers, batteries and other components may require aids for moving and positioning. Assess weight, grip, height, space and stability; do not make manual handling the only option because suitable resources are unavailable.

Plan raised-floor opening, cable installation and access to elevated components while maintaining safe routes. Royal Decree 487/1997 prioritises avoiding hazardous manual handling and reducing the risk when it cannot be avoided. Training complements, but does not replace, suitable methods and equipment.

Noise, thermal conditions and organisation

Ventilation and other equipment may generate noise: assess actual exposure by task and duration rather than assigning a fixed level to all centres. In Spain, Royal Decree 286/2006 governs its assessment and reduction.

Consider temperature differences between zones, exertion during interventions and maintenance conditions. Also review alerts, communication between teams, lone working and available assistance. Maintenance windows and urgent work must not result in plans that depend on fatigue or taking risks to finish on time.

Emergencies and coordination of interventions

Adapt alarms, evacuation and access for assistance to the facility’s actual characteristics. Where gaseous fire suppression systems exist, understand their operation and the conditions for safe exit and re-entry; do not assume every technical room is a confined space.

Coordinate simultaneous work and communicate which safeguards or services are temporarily affected. Establish who authorises the start, who knows the personnel’s situation and how normal conditions will be restored. Continuity tests must also incorporate people’s safety.

Hypothetical example: replacing backup equipment

A centre schedules battery replacement during a maintenance window. It identifies circuits and energy sources, agrees the sequence with competent personnel and provides aids for moving components without obstructing exits.

Contractors understand access, communication and emergency conditions. Before completion, the installation, safeguards and removal of materials are checked. The operation is planned around both service and safe work, without treating IT availability as a reason to omit controls.

References

  1. BOE. Royal Decree 614/2001 on electrical risk. Official source
  2. BOE. Royal Decree 487/1997 on manual handling of loads. Official source
  3. BOE. Royal Decree 286/2006 on noise exposure. Official source
  4. HSE. Emergency procedures. Official source

Editorial information

Publication date: 19 October 2026.

Editorial responsibility: Sabentis Editorial Team.

Author: Pablo RodríguezLinkedIn

Executive Vice President of the ORP International Foundation and Chief Financial Officer of Sabentis.