On this page
What it regulates
Brings together instructions on coal mines with explosion risks, special works, prospecting and electricity. This selection covers ventilation management, gas monitoring and protection of prospecting personnel.
Who it applies to
Selected provisions of RGNBSM chapters V and VI, with status context for chapter IX. Each ITC depends on the activity, mine classification and applicable territorial and electrical regime.
Key provisions
ITC 05.0.04. Gassy mines require continuous main ventilation; shutdowns during inactivity need mining-authority approval. Required checks must precede return after evacuation. The instruction also governs backup ventilation and checking the reversal system.
ITC 05.0.04ITC 05.0.05. It requires personnel trained in methane detection, checks before entry and records of anomalies, measurements and ventilation. On a dangerous gas release, personnel must leave, mark the location and notify their supervisor. Limits must be read with applicable subsequent legislation.
ITC 05.0.05ITC 06.0.01. A prospecting project must describe the work, machinery and safety measures. It requires technical management, trained and equipped personnel, and precautions for entering old workings. This selection does not replace current fall-protection rules or other prevention duties.
ITC 06.0.01ITC 06.0.07, amended in 1986. Groundwater prospecting and extraction safety are subject to mining supervision and prior project approval. Shaft deepening and advancing galleries follow the relevant rules, with particular attention to ventilation, travel and explosives.
ITC 06.0.07History and versions
BOE publication: 09/10/1985 · Initial entry into force: 29/10/1985
BOE-A-1985-20808Published on 9 October 1985; effective from 29 October 1985. History: a 1986 correction, the 1986 groundwater amendment, the 2007 electrical amendment, the 2017 repeal, the 2018 gas amendment and the 2020 electrical-personnel repeal. Order ETU/995/2017 additionally establishes the electrical framework and conditional retention of earlier provisions.
Replaces ITC 02.0.01 on technical management and repeals ITC 09.0.10 on electrical installation, operation and maintenance personnel.
BOE-A-2020-3853The Explosives Regulation repeals ITCs 09.0.07, 10.0.01, 10.0.02 and 10.1.01 in their respective original orders; it does not repeal those orders in full.
BOE-A-2017-2313Repeals section 1 of ITC 04.7.02 and amends ITC 05.0.02. Consult the subsequent framework for toxic and flammable gases.
BOE-A-2018-14894Amends chapter 3, section 3.1 of ITC 09.0.02; its current application must be read together with Order ETU/995/2017.
BOE-A-2007-11586Amends ITC 06.0.07 on safety in groundwater prospecting and extraction.
BOE-A-1986-14538Correction to the Order of 2 October 1985 published on 1 March 1986.
BOE-A-1986-5444Subsequent electrical-installation framework: articles 2 and 3 and the transitional provision preserve specified earlier ITCs only in the stated cases, without repealing the original orders in full.
BOE-A-2017-11908Text versions of the selected OSH provisions
| Publication | Effective date | Official reference | Affected provisions |
|---|---|---|---|
| 09/10/1985 | 29/10/1985 | BOE-A-1985-20808 | ITC 05.0.02, ITC 05.0.04, ITC 05.0.05, ITC 06.0.01, ITC 06.0.07, ITC 09.0.02, ITC 09.0.07, ITC 09.0.10 |
| 30/10/2018 | 30/04/2019 | BOE-A-2018-14894 | ITC 05.0.02 |
| 06/06/1986 | 26/06/1986 | BOE-A-1986-14538 | ITC 06.0.07 |
| 13/06/2007 | 14/06/2007 | BOE-A-2007-11586 | ITC 09.0.02 |
| 04/03/2017 | 05/03/2017 | BOE-A-2017-2313 | ITC 09.0.07 |
| 18/03/2020 | 07/04/2020 | BOE-A-2020-3853 | ITC 09.0.10 |
Transitional provisions and application notes
ITC 05.0.02 was amended by Order TEC/1146/2018. ITC 09.0.07 was repealed by Royal Decree 130/2017 and ITC 09.0.10 by Order TED/252/2020. These repeals do not cover the whole order.
ITC 05.0.02Electricity: Order ETU/995/2017 governs new installations and specified alterations or risks affecting existing installations (article 2). Its inspection regime applies to all, but article 3 retains the original approval criteria for certain older installations. Its transitional provision preserves only the listed earlier ITCs for installations outside the scope of the new ones. This order’s electrical chapter is not presented as a general rule for new installations.
Transitional provision soleTerritorial application: article 2 of Royal Decree 863/1985 distinguishes direct application of the ITCs, supplementary application in autonomous communities with regulatory powers, and regional rules. ITCs on standardisation and approval, and those on explosives, apply directly throughout Spain. The site’s regional rules must be checked.
Article 2
Official BOE legal relationships
This record covers the history of the selected occupational safety and health provisions. The official analysis also provides the relationships affecting other subjects in the legislation.
Official BOE legal relationshipsOfficial sources
- BOE-A-1985-20808 · Original text
- BOE-A-1985-20808 · Consolidated text
- ELI identifier
- BOE-A-2020-3853 · Original text
- BOE-A-2017-2313 · Original text
- BOE-A-2018-14894 · Original text
- BOE-A-2007-11586 · Original text
- BOE-A-1986-14538 · Original text
- BOE-A-1986-5444 · Original text
- BOE-A-2017-11908 · Original text
- BOE-A-2017-11908 · Consolidated text
- BOE-A-1985-10836 · Original text
- BOE-A-1985-10836 · Consolidated text
- BOE-A-1997-21178 · Original text
- BOE-A-1997-21178 · Consolidated text